
WE DO NOT STOCK ALL OF THE ITEMS SHOWN HERE. THEY ARE AVAILABLE AND WE CAN GET THEM BUT WE DO NOT KEEP EVERY ITEM IN STOCK.
List Prices (2012) List Prices (2012) List Prices (2012) List Prices (2012)
M-500 Pressure Drop Activated Trap Seal Primers
MIFAB® MR-500, M1-500 & M2-500 Series
pressure drop activated brass trap seal primer, with inlet opening of
1/2" male N.P.T. and outlet opening of female 1/2" N.PT. Complete with
four view holes and removable filter screen. Requires no adjustments and
no air pre-charge. MIFAB's Series of pressure activated trap seal
primers (MR-500, M1-500 and M2-500) can be connected to any cold water
line and will be automatically activated when a valve or faucet, that is
on the line, is ...
MI-DU Trap Seal Primer Distribution Unit
MIFAB's MI-DU trap seal primer
distribution unit is engineered to receive a metered amount of water
from a trap seal primer and distribute the water equally to either two,
three or four floor drain traps. Choose from either 1/2" or 5/8"
compression connections by indicating suffix (-500) for 1/2" or suffix
(-625) for 5/8". The lid of the distribution unit has the numbers "2",
"3" and "4" marked on it. The body of the distribution unit has a guide
marker on the top of the body.
The ...
MI-700 Gravity Fed Trap Seal Primers
MIFAB's MI-700 Series trap seal primers
are engineered to prime one floor drain trap that is no further than
twenty feet from the fixture supplying the prime. A 1/2" (13) O.D.
copper make-up water line connecting the trap seal primer to the floor
drain trap is recommended for the M700 & MI-701.
MI-730 P-Trap with Cleanout
List Prices (2011)
Function: Designed to collect and hold water at ...
MI-750 Tailpiece Trap Seal Primer with Braided Connecting Hose
List Prices (2011)
Function: Used to ...
MI-600 ABS/PVC "P-Trap" Trap Seal Primer Connectors
(12)
MIFAB Series MI-6 2-4 ABS or PVC
(specify) schedule #40 D.W.V. P-Trap trap seal primer connector, with 2"
(51) 3" (76), or 4" (102) (specify) pipe connections, and a 1/2" (13)
or 5/8" (16) (specify) brass compression fitting connection to attach to
a trap seal primer water supply line. The MIFAB MI-600 Series of P-Trap
trap seal primer connectors meet the ASTM D-2661 and ASTM D-2665
Standards.
MI-TEMP Automatic Pressure Balance Valve
The MI-TEMP holds a selected water
temperature to within one degree from any constant hot water supply
regardless of pressure changes in the supply lines. It ensures a blend
of mixed hot and cold water at the shower head and is fully automatic -
only one moving part will equalize the hot and cold supply line
pressures. As supply line pressures fluctuate, the brass piston will
move enough to compensate for the change in pressure and release water
only at the preselected ...
MI-100 Enclosed Electronic Trap Seal Primers
MI-100 Engineered for Equal Distribution at All Ports
The
perfect solution to keep sewer gas from entering the building from
seldom used floor drains. The MI-100 can be located anywhere in the
water supply and is engineered to permit the building owner to adjust
the frequency and amount of water delivery through a timer and solenoid
valve. An engineered distribution manifold ensures that a minimum of 2
ounces of water are delivered equally to every port over a twenty four ...
MI-200 Electronic Trap Seal Primers with Air Gap
(2)
The MI-200 is engineered to connect to
the voltage building energy management system used to manage the
services in commercial, educational, institutional buildings. It can be
located anywhere in the water supply.
MIFAB's MI-DU-625 is provided as part of the assembly so that up to 4 drains can be served.
The
MI-200 is practical for infrequently used buildings such as convention
centers and sports facilities. The MI-200 is manufactured in accordance
with ANSI/ASME A112.1.2 air ...
MI-300 Electronic Trap Seal Primers with Air Gap, Distribution Unit and Control Panel
(4)
MI-300 Electronic Trap Seal Primer
The
MI-300 is manufactured with a solenoid valve, air gap, distribution
unit and electronic controller. The water discharge frequency can be
adjusted to meet the building's needs. The MI-300 can be located
anywhere in the water supply. MIFAB's MI-DU distribution unit is
connected to the bottom of the MI-300 to serve up to 4 drains.
Additional distribution units can be added to serve up to 13 drains from
one MI-300 with standard soft ...
MI-300-ENC Electronic Trap Seal Primers with Air Gap, Distribution Unit, Control Panel and Enclosure
(4)
The MI-300-ENC is the some product as the MI-300-ENC except that it is assembled within an enclosure for easy installation.
MI-CT - Copper to ABS Transition
(4)
MI-TSP Series - Continuous Flow Trap Seal Primers
List Prices (2011)
MIFAB
Model MI-TSP-1 brass trap seal primer with removable poppet, integral
vacuum breaker, gasketed access cover, 1/2" (13) N.P.T. inlet and outlet
connections, complete with 1/2" (13) sweat ...
MI-600-50 Series - Cast Iron P-Trap Seal Primer Connectors
List Prices (2011)
WE DO NOT STOCK ALL OF THE ITEMS SHOWN HERE. THEY ARE AVAILABLE AND WE CAN GET THEM BUT WE DO NOT KEEP EVERY ITEM IN STOCK.
Translate This Page
3137 BAILEY AVE., BRONX, NEW YORK |
